Frequently Asked Question
During a SIL verification process a query was raised as to whether the mission time in the software can be equal to the plant turnaround, or should it be equal to the time from plant start-up to the replacement or refurbishment to as-new condition of the
Last Updated 5 years ago
The mission time represents the time until complete replacement of all devices in your SIF. The main turnaround time mentioned in the user guide is talking about this. If you set the mission time to 12 months as in your example above, you would basically stating that all equipment is replaced /refurbished at that time.